"Check Salt" and "Inspect Cell" lights are on
1.Check that the cell corresponds to the model of the electrolyser by comparing the references (serial number) on the cell, the device as well as on the internal program if it is not the case to match the cell with the program on the device "mode" then "cell type"
2.Variable speed pump, the water flow is too low it will be necessary to increase the pump speed
3.The temperature sensor inside the cell is faulty (gap greater than 2°C between the pool water and the display) a service file must be made
4.The cell is clogged it will be necessary to remove the celula.
5.The actual salinity is less than 2300 PPM salt must be added
6.The cell is failing
7.Power board is defective
in the last two cases, a service file must be made