The factory reset of your heat pump can be done in two methods for single-phase models, with a dedicated method for three-phase models.
Single-Phase Model - Method 1:
- Simultaneously press the "On/Off" button and the fourth button from the left for 5 seconds.
- Press the down arrow multiple times until reaching parameter F60.
- Press the fourth button from the left to access the parameter.
- Press the up arrow to display "F60 001."
- Confirm the parameter by pressing the fourth button from the left.
- After 15 seconds, the display on the unit will show "F60 000."
The reset of your heat pump to factory settings is now complete.
Single-Phase Model - Method 2:
- Simultaneously press the "On/Off" button and the up arrow for 5 seconds.
- Press the down arrow multiple times until reaching parameter F60.
- Press the fourth button from the left to access the parameter.
- Press the up arrow to display "F60 001."
- Confirm the parameter by pressing the fourth button from the left.
- After 15 seconds, the display on the unit will show "F60 000."
The reset of your heat pump to factory settings is now complete.
Three-Phase Model:
Hold down all buttons, except the "On/Off" button, for a duration of 5 seconds.
The reset of your three-phase heat pump is now complete.